Model |
UCP3522-1250P20/C |
UCP3542-0650P20/C |
UCP5542-1050P20/C |
| Utility input | |||
| Utility Input Voltage | 176VAC to 264VAC (Default) 90VAC to 285VAC (Configurable) |
||
| Utility Input Frequency | 45Hz to 65Hz | ||
| Maximum Utility Charging Current | 110A | 60A | 100A |
| Switch Response Time | Switch Response Time – Inverter to Utility: 10ms Switch Response Time – Utility to Inverter (when the load power is higher than 100W): 20ms |
||
| Inverter output | |||
| Inverter Rated Power (@30℃) | 3500W | 5500W | |
| 3-second Transient Surge Output Power | 7000W | 8500W | |
| Inverter Output Voltage | 220/230VAC±3% | ||
| Inverter Frequency | 50/60Hz±0.2% | ||
| Output Voltage Waveform | Pure sine wave | ||
| Load Power Factor | 0.2-1(VA ≤ Rated output power) | ||
| THDu (Total Harmonic Voltage Distortion) | ≤3% | ||
| Maximum Load Efficiency | 92% | ||
| Maximum Inverter Efficiency | 94% | ||
| Maximum Main Load | 3500W | 5500W | |
| Maximum Second Load | 3500W | 5500W | |
| Main Output Cut-Off Voltage | Equal to “Under Voltage Warning Voltage” | ||
| Second Output Cut-Off Voltage | Equal to “Low Voltage Disconnect Voltage” | ||
| Dual Output Recovery Voltage | Equal to “Low Voltage Reconnect Voltage” | ||
| Solar controller | |||
| PV Maximum Open-circuit Voltage | 500V (At minimum operating environment temperature) 440V (At 25℃) |
||
| MPPT Voltage Range | 85V to 450V | ||
| Number of MPPTs | 1 | 2 | |
| PV Maximum Input Current | 20A | 20A+20A | |
| PV Maximum Short-circuit Current | 22A | 22A+22A | |
| PV Maximum Input Power | 4200W | 2×3300W | |
| PV Maximum Charging Current | 120A | 60A | 100A |
| MPPT Maximum efficiency | ≥99.5% | ||
| Battery | |||
| Battery Rated Voltage | 24VDC | 48VDC | |
| Battery Work Voltage Range | 20.4VDC to 32.0VDC | 40.8VDC to 64.0VDC | |
| Battery Maximum Charging Current | 120A | 60A | 100A |
| Others | |||
| No-load Losses | ≤1.5A | ≤0.8A | ≤1.1A |
| Test condition: Utility, PV and Load are disconnected, AC output is ON, fan stops, @24V input | Test condition: Utility, PV and Load are disconnected, AC output is ON, fan stops, @48V input | ||
| Standby Current | ≤1.1A | ≤0.6A | ≤0.8A |
| Test condition: Utility, PV and Load are disconnected, AC output is OFF, fan stops, @24V input | Test condition: Utility, PV and Load are disconnected, AC output is OFF, fan stops, @48V input | ||
| Communication with BMS | RS485 | ||
| Communication with Portal | RS485 | ||
| Parallel Function | Yes, 12 units in standard, 16 units at most | ||
| Work Temperature Range | -20℃ to +50℃ (When the environment temperature exceeds 30℃, the actual output power is reduced appropriately) | ||
| Storage Temperature Range | -25℃ to +60℃ | ||
| Enclosure | IP20 (With ANTI-DUST KIT) | ||
| Relative Humidity | < 95% (N.C.) | ||
| Altitude | <4000M (If the altitude exceeds 2000 meters, the actual output power is reduced appropriately) | ||
| Certifications and Standards | IEC 62109-1, IEC 62109-2, IEC 61683, IEC 62368 | ||
| Mechanical parameters | |||
| Dimension (Length x Width x Height) | 590mm × 300mm × 163mm | 534mm × 300mm × 163mm | 590mm × 300mm × 163mm |
| Mounting size (Length x Width) | 568mm × 245mm | 512mm × 245mm | 568mm × 245mm |
| Mounting hole size | Φ9mm/Φ10mm | ||
| Net Weight | 13.8Kg | 12.7Kg | 15.5Kg |