Description
Additional Information
Model |
UC3522-1250P20/C |
UC3542-0650P20/C |
UC5542-1050P20/C |
UC6042-1250P20C |
| Utility input | ||||
| Utility Input Voltage | 176VAC to 264VAC (Default) 90VAC to 285VAC (Configurable) |
|||
| Utility Input Frequency | 45Hz to 65Hz | |||
| Maximum Utility Charging Current | 110A | 60A | 100A | 100A |
| Switch Response Time | Switch Response Time – Inverter to Utility: 10ms Switch Response Time – Utility to Inverter (when the load power is higher than 100W): 20ms |
|||
| Inverter output | ||||
| Inverter Rated Power (@30℃) | 3500W | 5500W | 6000W | |
| 3-second Transient Surge Output Power | 7000W | 8500W | 12000W | |
| Inverter Output Voltage | 220/230VAC±3% | |||
| Inverter Frequency | 50/60Hz±0.2% | |||
| Output Voltage Waveform | Pure sine wave | |||
| Load Power Factor | 0.2-1(VA ≤ Rated output power) | |||
| THDu (Total Harmonic Voltage Distortion) | ≤3% (24V resistive load) | ≤3% (48V resistive load) | ||
| Maximum Load Efficiency | 92% | |||
| Maximum Inverter Efficiency | 94% | |||
| Maximum Main Load | 3500W | 5500W | 6000W | |
| Maximum Second Load | 3500W | 5500W | 6000W | |
| Main Output Cut-Off Voltage | Equal to “Under Voltage Warning Voltage” | |||
| Second Output Cut-Off Voltage | Equal to “Low Voltage Disconnect Voltage” | |||
| Dual Output Recovery Voltage | Equal to “Low Voltage Reconnect Voltage” | |||
| Solar controller | ||||
| PV Maximum Open-circuit Voltage | 500V (At minimum operating environment temperature) 440V (At 25℃) |
|||
| MPPT Voltage Range | 85V to 450V | |||
| Number of MPPTs | 1 | 2 | 2 | |
| PV Maximum Input Current | One way, 16A | Two ways, 2x16A | Two ways, 2x16A | |
| PV Maximum Short-circuit Current | One way, 18A | Two ways, 2x18A | Two ways, 2x18A | |
| PV Maximum Input Power | 4200W | 2×3300W | 8000W | |
| PV Maximum Charging Current | 120A | 60A | 100A | 120A |
| MPPT Maximum efficiency | ≥99.5% | |||
| Battery | ||||
| Battery Rated Voltage | 24VDC | 48VDC | ||
| Battery Work Voltage Range | 20.4VDC to 32.0VDC | 40.8VDC to 64.0VDC | ||
| Battery Maximum Charging Current | 120A | 60A | 100A | 120A |
| Others | ||||
| No-load Losses | ≤1.5A | ≤0.8A | ≤1.1A | ≤1.1A |
| Test condition: Utility, PV and Load are disconnected, AC output is ON, fan stops, @24V input | Test condition: Utility, PV and Load are disconnected, AC output is ON, fan stops, @48V input | |||
| Standby Current | ≤1.1A | ≤0.6A | ≤0.8A | ≤0.8A |
| Test condition: Utility, PV and Load are disconnected, AC output is OFF, fan stops, @24V input | Test condition: Utility, PV and Load are disconnected, AC output is OFF, fan stops, @48V input | |||
| Communication with BMS | RS485 | |||
| Communication with Portal | RS485 | |||
| Parallel Function | Yes, 12 units in standard, 16 units at most | |||
| Work Temperature Range | -20℃ to +50℃ (When the environment temperature exceeds 30℃, the actual output power is reduced appropriately) | |||
| Storage Temperature Range | -25℃ to +60℃ | |||
| Enclosure | IP20 (With ANTI-DUST KIT) | |||
| Relative Humidity | < 95% (N.C.) | |||
| Altitude | <4000M (If the altitude exceeds 2000 meters, the actual output power is reduced appropriately) | |||
| Certifications and Standards | IEC 62109-1, IEC 62109-2, IEC 61683, IEC 62368 | IEC 62109-1,IEC 62109-2,IEC 61683 | ||
| Mechanical parameters | ||||
| Dimension (Length x Width x Height) | 590mm × 300mm × 163mm | 534mm × 300mm × 163mm | 590mm × 300mm × 163mm | 590mm × 300mm × 163mm |
| Mounting size (Length x Width) | 568mm × 245mm | 512mm × 245mm | 568mm × 245mm | 568mm × 245mm |
| Mounting hole size | Φ9mm/Φ10mm | Φ9mm/Φ10mm | Φ9mm/Φ10mm | Φ9mm/Φ10mm |
| Net Weight | 13.8Kg | 12.7Kg | 15.5Kg | 15Kg |