Parameter LSLV0075SP100-4CEFD / SP100
Model / Series LSLV0075SP100-4CEFD / SP100 Series
Rated motor power HD: 7.5 HP (5.5 kW) · ND: 10 HP (7.5 kW)
Input voltage 3-phase 380–480 VAC (export / 480 VAC nominal)
Output 3-phase 240 VAC (to motor)
Rated output current HD: 12 A · ND: 16 A
Output frequency 0–400 Hz
Mounting Packaged cabinet (vertical/wall); shipped as NEMA-1 packaged unit
Enclosure / Protection UL Type 1 / NEMA-1 (indoor)
EMC filter Built-in
Communications Built-in Modbus RTU (LS-INV485) ; optional Dual Port EtherNet/IP, Modbus TCP, BACnet/IP, LonWorks
Certifications UL / cUL / CE / KC; SCCR info in LS docs
Ambient temp -10 to +50 °C (HD) / -10 to +40 °C (ND)
Dimensions (approx.) 168.9 × 927.4 × 226.7 mm

Buy Now

Description

LS Electric — LSLV0075SP100-4CEFD (SP100 — Packaged Bypass VFD)

Packaged SP100 bypass VFD for 3-phase 480 VAC systems with integrated 3-contactor bypass, built-in DC reactor and built-in EMC filter (CEFD); aimed at HVAC fan/pump applications where continuity and EMC performance matter.

The Polar Energy Assessment:

This is the 480 VAC packaged SP100 solution that balances continuous-operation bypass capability with EMC compliance (built-in filter) and compact NEMA-1 cabinet mounting. It’s ideal for retrofit and new HVAC pump/fan installations that require automatic/manual bypass and better conducted-emission control. Be aware: it’s a UL Type 1 / indoor package (not intended for direct outdoor exposure).

 

Pros

  • Integrated 3-contactor bypass (HAND/OFF/AUTO) for maintenance with no process downtime.
  • Built-in DC reactor and built-in EMC filter (CEFD suffix) for reduced harmonics and conducted emissions.
  • Built-in communications and BAS options (Modbus/BACnet/EtherNet options).
  • Packaged NEMA-1 (UL Type 1) cabinet for quick retrofit installs.

Limitations

  • Indoor / UL Type 1 only — needs enclosure if outdoors or in wet/dusty areas.
  • Packaged unit increases cabinet footprint compared with a bare drive + custom panel.

 

Typical use cases

  • HVAC central plant pumps and large fans requiring bypass for serviceability.
  • Retrofit of 480 VAC motor control centers to add VFD control + bypass.
  • Sites with stricter EMC requirements where built-in filtering reduces external hardware.