LS Electric LSLV0055SP100-4CEFD Inverter VFD Low Voltage Drive

Parameter LSLV0055SP100-4CEFD
Model / Series LSLV0055SP100-4CEFD / SP100 Series
Rated motor power HD: 5 HP (3.7 kW); ND: 7.5 HP (5.5 kW)
Input voltage 3Φ 380–480 VAC (nominal)
Output 3Φ AC (to motor)
Rated output current HD: 8 A; ND: 12 A
Output frequency 0–400 Hz
Mounting Panel/wall (vertical)
Enclosure / Protection NEMA 1 (UL Type 1)
EMC filter Built-in (standard)
Communications Modbus RTU, LS-INV485 (built-in); Option: RAPIEnet+, Ethernet/IP, Modbus TCP, BACnet/IP
Certifications UL, cUL, CE, KC; SCCR 100 kA (IEC 60439-1)
Ambient temp HD: –10–50 °C; ND: –10–40 °C
Dimensions (approx.) 168.9 × 927.4 × 226.7 mm (6.65×36.61×8.93 in)

Buy Now

Description

LSLV0055SP100-4CEFD

A 7.5 HP (5.5 kW) SP100-series drive for 3Φ 380–480 VAC systems. It offers the same integrated contactor bypass and V/F control as the 240 VAC version, now for 460 VAC supply. This model includes a built-in EMC filter for noise suppression, making it suitable for higher-voltage installations.

The Polar Energy Assessment:

This drive is the 380–480 VAC variant of the SP100 packaged series. It provides 5 HP heavy-duty or 7.5 HP normal-duty output to a 240 VAC motor, with slip-compensated V/F drive and built-in DC reactor. It includes all SP100 features (auto bypass, overload protection, communications) plus an internal EMC filter to meet tighter standards at 460 VAC. Strengths include continuous-operation bypass and built-in protocols, now with added EMC compliance. Trade-offs are similar to the 240 VAC model: it is indoor-only (NEMA 1) with fixed 3Φ input and 12 A output (limiting to ~5.5 kW). Like the 240V version it is rated –10–50 °C (HD) and meets 100 kA SCCR requirements, but it does not support single-phase input or advanced vector control.

Pros

  • Integrated bypass and auto-transfer (no downtime)
  • Built-in EMC filter (reduces conducted noise)
  • Built-in DC reactor (standard)
  • Compact NEMA1 enclosure with easy wiring
  • Supports BACnet/Metasys/Modbus (built-in)
  • High SCCR (100 kA, IEC 60439-1)

Limitations

  • No outdoor protection (NEMA1, UL Type 1)
  • Fixed 3Φ 480 VAC input (no 3Φ 230 VAC option)
  • Moderate output current (8 A HD / 12 A ND at 480 VAC) limits maximum motor power.
  • Only V/F control method (no high-performance vector control)

Typical use cases

  • Large HVAC systems (e.g. cooling pumps, rooftop unit fans) needing 480 VAC drives with bypass
  • Building automation integration: 480 VAC drives in facilities using BACnet or Metasys for centralized control
  • Retrofit of 460 VAC motor controls: Upgrading legacy pump/fan panels to include bypass and communication.
  • Industrial ventilation/exhaust: Medium-duty motors requiring energy savings and backup operation.