Description
Additional Information
Model |
HP3522-AH1250P65A |
HP3542-AH0650P65A |
HP5542-AH1050P65A |
| Utility input | |||
| Utility Input Voltage | 176VAC~264VAC (Default), 90VAC~280VAC (Configurable) | 176VAC~264VAC (Default), 90VAC~280VAC (Configurable) | |
| Utility Input Frequency | 45Hz~65Hz | 45Hz~65Hz | |
| Maximum Utility Charging Current | 110A | 60A | 100A |
| Switch Response Time | Switch Response Time – Inverter to Utility: 10ms Switch Response Time – Utility to Inverter (when the load power is higher than 100W): 20ms |
Switch Response Time – Inverter to Utility: 10ms Switch Response Time – Utility to Inverter (when the load power is higher than 100W): 20ms |
|
| Inverter output | |||
| Inverter Rated Power (@30℃) | 3500W | 3500W | 5500W |
| 3-second Transient Surge Output Power | 7000W | 7000W | 8500W |
| Inverter Output Voltage | 220/230VAC±3% | 220/230VAC±3% | |
| Inverter Frequency | 50/60Hz±0.2% | 50/60Hz±0.2% | |
| Output Voltage Waveform | Pure Sine Wave | Pure Sine Wave | |
| Load Power Factor | 0.2~1(VA ≤ Rated output power) | 0.2~1(VA ≤ Rated output power) | |
| THDu (Total Harmonic Voltage Distortion) | ≤3% (24V resistive load) | ≤3% (48V resistive load) | |
| Maximum Load Efficiency | 89% | 92% | 91% |
| Maximum Inverter Efficiency | 93% | 94% | 94% |
| Solar controller | |||
| PV Maximum Open-circuit Voltage | 500V (At minimum operating environment temperature) 440V (At 25℃) |
500V (At minimum operating environment temperature) 440V (At 25℃) |
|
| MPPT Voltage Range | 85~400V | 85~400V | |
| Number of MPPTs | 1 | 1 | 2 |
| PV Maximum Input Current | One way, 20A/way | One way, 20A/way | Two ways, 2x15A |
| PV Maximum Input Power | 4000W | 4000W | 2×3000W |
| PV Maximum Charging Current | 120A | 60A | 100A |
| MPPT Maximum efficiency | ≥99.0% | ≥99.5% | |
| Battery | |||
| Battery Rated Voltage | 24VDC | 48VDC | |
| Battery Work Voltage Range | 21.6VDC~32.0VDC | 43.2VDC~64VDC | |
| Battery Maximum Charging Current | 120A | 60A | 100A |
| Others | |||
| No-load Losses | <1.3A | <0.6A | <1.0 A |
| Test condition: Utility, PV and Load are disconnected, AC output is ON, fan stops, @24V input | Test condition: Utility, PV and Load are disconnected, AC output is ON, fan stops, @48V input | ||
| Standby Current | <0.3A Test condition: Utility, PV and Load are disconnected, AC output is OFF, fan stops, @24V input | <0.15A Test condition: Utility, PV and Load are disconnected, AC output is OFF, fan stops, @48V input | |
| Work Temperature Range | -20℃~+55℃ (When the environment temperature exceeds 35℃, the actual output power is reduced appropriately) | -20℃~+55℃ (When the environment temperature exceeds 35℃, the actual output power is reduced appropriately) | |
| Storage Temperature Range | -25℃~+60℃ | -25℃~+60℃ | |
| Enclosure | IP65 | IP65 | |
| Relative Humidity | < 100% (N.C.) | < 100% (N.C.) | |
| Altitude | <4000M (If the altitude exceeds 2000 meters, the actual output power is reduced appropriately) | <4000M (If the altitude exceeds 2000 meters, the actual output power is reduced appropriately) | |
| Mechanical parameters | |||
| Dimension (Length x Width x Height) | 545mm × 428mm × 248mm | 537mm × 428mm × 246mm | 545mm ×428mm ×248mm |
| Mounting Size (Length x Width) | 350mm x 130mm | 350mm x 130mm | 350mm x 130mm |
| Mounting Hole Size | Φ10mm | Φ10mm | Φ10mm |
| Net Weight | 25.0kg | 21.0kg | 25.4kg |
Download
📥 EPEVER-DataSheet-HP-AHP65A-Series